Hongwei-What you care about is what we care about
  • HWR(V)-40.5/T630-20 Load switch circuit breaker switch

HWR(V)-40.5/T630-20 Load switch circuit breaker switch

The SF6-40.5/T630-20kA-type high-voltage switch is designed for control and protection in 40.5kV power transmission and distribution systems, effectively managing load current switching and interrupting short-circuit currents. Featuring a modular design, it delivers compact structure, superior interrupting performance, high reliability, extended service life, full insulation, maintenance-free operation, and space-efficient configuration. This versatile device is widely applicable in industrial, commercial, and residential grid networks, as well as end-user power supply systems. It is particularly suitable for small secondary distribution substations, switchgear stations, industrial facilities, airports, railways, highways, subways, commercial districts, residential communities, wind farms, and photovoltaic power generation applications.


Service Hotline

0577-62686971

Model composition and meaning

HWSF6-40.5/T630-20


Operating conditions

 installation site

In the box

 ambient temperature (℃)

-45~+140

 height (m)

≤2000

 air humidity (%)

The daily average is not greater than 95% and the monthly average is not greater than 90%

 seismic intensity

No more than 8 degrees

 

Technical parameters of circuit breaker

 order number

Main equipment and technical performance

Parameters and requirements

1

 circuit breaker

1 unit

•  type

Fixed vacuum circuit breaker

•  rated voltage

40.5kV

•  rated current

630A

•  rated frequency

50Hz

• Peak lightning impulse withstand voltage (breakout/ground)

≥215kV/185kV

• 1min power frequency withstand voltage (breakout/ground)

≥118kV/95kV

• Rated short-time power frequency withstand voltage of auxiliary circuit

2kV、50HZ 1min

• Rated short-term withstand current

20kA

• Rated peak withstand current

50kA

• Rated short circuit breaking current

20kA

• Rated short-circuit closing current

50kA

• Rated short circuit duration

≥4s

 

• Operating mechanism

 type

Spring operating mechanism

 control voltage

DC 24V/48V/110V/220V

Auxiliary contacts

6 always on, 6 always off

 

•  mechanical life

Rated operating sequence

O-0.3s-CO-180s-CO

 mechanical life

10,000 times

• Electrical life


10,000 times

 

•  mechanical properties

Closing and opening time

35-70ms

Comb and split speed

1.2-1.9mm/s

 clearance between open contacts

18-22mm

Three-phase coincidence and different phase separation

≤3ms

2

Three position isolating switch

1 unit

•  type

Manual/ Electric

3

• Auxiliary contacts

3 always on, 3 always off

•  mechanical life

2,000 times

• Electrical life of grounding switch

2,000 times

4

Cabinet dimensions

Not larger than 600X1700 (width X depth)

 

Mechanical characteristics of circuit breaker

 order number

 inspecting item

 technical requirement

1

Check the main switch of the circuit breaker

Number of arc extinguishing chamber (indicate manufacturer)

The opening distance is 18-22mm

Exceeding the limit by 3±1mm

Contact pressure ≥ 3000N

2

Mechanical properties inspection

The difference between three-phase phase separation is less than 2ms

The difference between three-phase closing time is less than 2ms

Average speed of commutation 1.4-2.0m/s

Average closing speed 1.0-1.8m/s

3

Circuit breaker circuit

Loop resistance ≤45μΩ

 


Service Hotline

13738766792
  • logo
  • Production address:

    No. 333, Weishiqi Road, Yueqing Economic Development Zone, Zhejiang Province

  • Service hotline: 13738766792 Manager Xu 13777731466 Manager Xu
  • Email: 848160667@qq.com